Water cooler is an ehf wc hac or emabf series water cooler.
Elkay bottle filler troubleshooting.
Water cooler is an ez htv or electric eye operated model.
Purged through the bottle filler carefully inspect all water connections for leaks.
Troubleshooting guide problem cause corrective action problem cause corrective action problem cause corrective action regulator screw is turned all of the way clockwise and the flow is still too low.
Verify proper dispensing by placing cup hand or any opaque object in front of sensor area and verify water dispenses.
This article is for facility maintenance technicians who service elkay bottle filler units and need a resource for both how to change an elkay ezh20 filter in a bottle filler and how to reset the filter light on their elkay bottle filler unit after a new filter is installed.
Water stream is too high.
Read the article to check out all of the educational materials related to elkay ezh20 filter replacement as well as how.
Find correct wire.
This article contains some of the most common q a s pertaining to elkay ezh2o troubleshooting and maintaining commercial water cooler and bottle filler units.
Verify cable connector is plugged into led board in the bottle filler tower assembly.
Replace push bar or repair the cause of the sticking press bar such as the basin hanging on the mounting bracket for ez model or the press bar screw too tight on the htv model.
No water flow on all other water coolers fountains.
Regulator is not stopping the water.
Close and lock the lower panel in place using two set screws provided on the side of the panel.
Verify cable connector is plugged into control board 18 pin connector on harness 1000001608 replace led filter status board with repair kit 1000002436 kit alpha numeric led.
The seamless design of elkay ezh2o makes them easy to install keep clean and properly maintained with a little bit of attention and care.
Restore power to outlet.
Press bar adjustment screw has not been adjusted properly.
Elkay s ezh2o bottle filling stations are ideal for many environments both indoor and outdoor including education commercial health care fitness clubs and hospitality and more.
Model cause corrective action water cooler is an ez htv orelectric eye operated model 1 no power to outlet.
Learn how to p.
Verify cable connector is fully plugged into the basin from the tower assembly.
For the elkay ezh2o bottle filling stations such as model lzs8wslk lzs8wssk ezs8wslk use elkay sensor replacement part model number 98544c.