The report will also.
Emergency light testing frequency.
Code of practice for the emergency lighting of premises.
Emergency light testing frequency by law topic summary.
The option you choose for testing your emergency lighting system will depend on the type of system you have whether it is or is not a battery.
Emergency lighting usually takes effect automatically to provide sufficient levels of light for a minimum period of time in the event of sudden failure or loss of mains power supply.
The standard approach is to test the lighting every quarter with 4 visits a year.
Additional information on servicing can be found in bs 5266 1.
What do the regulations require.
Annual emergency lighting testing.
18 march 2016 08 22 am status.
The full duration test checks that the light stays on for the required time stated in bs5266 part 1 which is usually 3 hours.
The annual test should be a full rated duration test to ensure that the emergency lights are still working and producing the acceptable level of light at the end of the test.
After emergency lighting test we will issue you with detailed reporting outlining the health of your emergency lighting.
It is critical in facilitating safe exit and evacuation from a building with minimal panic.
Meet the code requirements or assume the risk.
The frequency of emergency light testing depends on the environment probability analysis and plausible alternatives.
Bs en 50172 bs 5266 8 emergency escape lighting systems specify the minimum provision and testing of emergency lighting for different premises.
These three factors are critical to the decision regarding emergency lighting testing.
Emergency lighting must be tested 4 times a year.
Emergency light testing frequency.
But it is lsc sections 5 9 3 and 31 1 3 7 and standard fire prevention code 1999 that specifically address the frequency of checking and testing the emergency exit lights.
18 march 2016 08 22 am.
Emergency lighting including exit signage is subject to a 30 second test every month and an annual 90 minute test to ensure that the system will function correctly in the event of an emergency.
7 9 3 periodic testing of emergency lighting equipment.
The annual inspection of your emergency lighting involves checking that the lighting unit activates correctly in a simulated loss of power situation as well as a full duration test.
So for example if a luminaire is rated for a 3 hour duration then after 3 hours in an emergency situation the light should still be lit.
The code provides three options for periodic testing of your emergency lighting equipment and another option pertaining to testing of your epss.